From design to recorded evidence.

A working bench prototype supports controlled chamber tests, recorded sensing data and a monitoring interface.

VELA prototype visualization
Bench setup

A controlled environment.

The acrylic chamber, replaceable test fixtures, pressure measurement and film sensors allow us to study different stages of an experiment.

Top view
Integrated test hardware
Leak fixture
Replaceable test fixture
Recorded data / AIN1 + AIN8

Two channels, different responses.

Recorded one-second RMS features show different signal intensities during evacuation and air-release stages.

Measured AIN1 and AIN8 RMS after 50 Hz notch across experiment stages
Source: VELA chamber experiment. 1-second RMS after 50 Hz attenuation; later segment unlabeled. Click to open full-size chart.
The recorded data confirms signal acquisition and observable responses. Multi-channel area ranking is the next validation step; the curve alone does not establish leak location.
In the lab

Watch the prototype in operation.

Test platform operation

Chamber and connected sensing hardware.

Signal monitoring

Recorded signal and monitoring workflow.

Power and acquisition

Prototype startup and indicator activity.

Planned comparative tests

How the next trials will be evaluated

Building on recorded two-channel data, the next stage will compare sensor responses across known leak locations. The test matrix and number of repeats will be adapted to the experimental setup, with consistent conditions for each group of trials.

PLANNED TESTSEVALUATION
01

Normal condition

No induced leak; otherwise comparable setup.

False alerts

False alerts and whether normal remains normal.

02

Different regions

Known leak positions with repeated trials.

Top-1 / top-2 ranking

Whether the true region is ranked first or in the top two.

03

Leak size and interference

Vary opening size and introduce controlled disturbances.

Stability & response time

Ranking stability and response time.

04

Data quality

Record offline, missing or saturated channels.

Insufficient evidence

Whether insufficient evidence is recognized.

Control the setup

Keep initial pressure, sensor mounting, recording window and acquisition settings consistent within each comparison.

Keep an auditable record

Record the condition, known leak position, channel data and interruptions. Retain raw records separately from processed features.